InMotionKFProOvenAutosampler(10mL)
PowerfulandVersatile.TheInMotionKFautosamplerisdesignedforwaterdeterminationbytheovenextractiontechnique.Uponheatingtothesample-specifictemperature,thewaterevaporatesandistransferredintothetitrationvesselbyastreamofdryairornitrogen.
AccuratelyDetermineOptimalTemperature
TemperatureScanprovidesgreatmeasurementperformanceindeterminingtheidealheatingtemperatureofasubstanceinjustasinglerun.
FlexIBLeMethodFunctionality
Knowyourdataispreciseandcanbetrusted.TheInMotionKFProcanautomaticallycheckwaterstandardsbeforeandaftereverysampleseries.
EfficientSamplePreparation
Theinnovativeone-piececapincreaseslabefficiencyenablingsimple,safeandfastsamplepreparationwithareducedchanceofchemicalexposure.
| Compatibletitrators | ExcellenceTitrators(T7&T9)CompactTitrators(C30SX,C30SD,V30S) |
| Integrateddigitalgasflowmeter | Yes |
| LabX®TitrationExpress/Server | Yes |
| AP200AirPump | Yes |
| SV2GasStopValve | Yes |
| Heatedtransfertube | Yes |
| Solventmanager | Yes |
| SP280PeristalticPump | Yes |
| Vialvolume(borosilicateglass) | 10ml |
| Captype | One-pieceFEPscrewcap |
| Dimensions(WxDxH) | 250mmx390mmx447mm |
| Weight | 9.3kg |
| Sensoraccuracy | +/-5ml/min |
| TemperatureCompensation | Yes |
| Supportedgases | Air,nitrogen |
| TemperatureRange | 40°C–280°C |
| Accuracy | +/-3°C |
| StABIlity | +/-0.5°C |
| Reproducibility | +/-0.5 |
| HeatingRate(/min) | 70°C/min |
| Coolingrate(forT>100°C) | >20°C/min |
| MaterialNumber(s) | 30407502 |
ChooseYourSampleSize
Analyzeupto24-10mLsamplesinasinglerun,orcontactusaboutourrackcustomizationpossibilities.
DirectControl
TheInMotionTMKFautosampleriscompletelycontrolledbythetitratororLabXSoftware:Allparameters,suchastheoventemperature,heatingrate,andflowrate,canbesimplystoredinmethods.
DoubleEfficiencyintheLab
Analyze2samplesinparallelbyconnectinguptotwoInMotionKFovenswithT9titrators-savingtime,benchspace,andboostingproductivity
UnattendedSolventExchange
TheSolventManagerautomaticallyreplacessolventsduringarunwhenusedwiththePeristalticPumpSP280.Increasebothproductivityandusersafetywhileavoidingincorrectresultsduetoexhaustedsolvents.
At-a-GlanceStatusInformation
TheStatusLightonthetopoftheInMotionKFshowyouimmediatelyifyouranalysisisstillrunning,needsyourattention,orisreadytorunmoresamples.UseLabXtoemailresultsoramessagetonotifyyouofthecurrentstatuswhenyou""renotinthelab.
SecureGasFlowControl
Controltheefficiencyofthewaterextractionwithdigitalgasflowcontrol.GenerategaswiththeAirPumpAP200orregulatewithanSV2valve.